START HERE |
|
Register | FAQ | PM | Events | Groups | Blogs | Calendar | Mark Forums Read |
Unregistered
|
FMA/Revolectrix Product Support FMA/Revolectrix Factory Product Support |
|
LinkBack | Thread Tools | Display Modes |
10-20-2014, 10:38 AM | #1 (permalink) |
Registered Users
Join Date: Dec 2010
|
PL 8 Issues
Hi Guys,
Need advice. Haven't flown for a month decided to charge up the Lipos but the charger keep showing bad cell count. Settings all check out correct. Anyway to self trouble shoot this issue. Btw all lipos are in good condition Thnaks |
Sponsored Links | |||
Advertisement |
|
10-20-2014, 10:57 AM | #2 (permalink) |
Registered Users
|
Are you using a parallel board or a balance adapter? I've had pins go bad on both.
The error code means it's not seeing the right number of cells (voltage from pins) for the total pack voltage. As a safety measure, it won't let you charge that way.
__________________
Team MikadoUSA |
10-20-2014, 10:58 AM | #3 (permalink) |
Registered Users
Thread Starter
Join Date: Dec 2010
|
I just measured the balance plugs on the MPA board & all
measured fine. Looks like the problem is within the charger. Thks |
10-20-2014, 10:59 AM | #4 (permalink) |
Registered Users
Thread Starter
Join Date: Dec 2010
|
Hi Hemp
Its a para charging board. Have always work till now |
10-20-2014, 11:19 AM | #5 (permalink) |
Registered Users
Thread Starter
Join Date: Dec 2010
|
When charger is powered up & using a DVM to measure the balance plugs
on the MPA balance board, should there be any readings on the pins ? I see a reading of 0.13 volts Thanks |
10-20-2014, 12:20 PM | #6 (permalink) |
Registered Users
|
What parallel board are you using? What firmware version and wiring mode are you running?
__________________
Revolectrix Ambassador - Charger Specialist Revolectrix.com 10% discount for Batteries GCAM16 |
10-20-2014, 07:33 PM | #7 (permalink) |
Registered Users
Thread Starter
Join Date: Dec 2010
|
Firmware v3.31, Revo parallel board & set to XH mode Gregor
Thks |
10-20-2014, 08:04 PM | #8 (permalink) |
Registered Users
|
I would plug a pack into the board, but do not connect to the charger. Use DVM to check voltages at the main leads that would go into the charger. Then do a pin by pin check of the balance cable that goes into the charger. Start at pins 1 and 2. That will be cell #1. Then move to pins 1 and 3. That's cell 1 and 2. Keep going until you've checked all cells.
If a main fuse is blown or pins on one of the contacts need cleaning, it can be hard to spot visually.
__________________
Revolectrix Ambassador - Charger Specialist Revolectrix.com 10% discount for Batteries GCAM16 |
10-21-2014, 04:14 AM | #9 (permalink) |
Registered Users
Thread Starter
Join Date: Dec 2010
|
Hi Gregor
Yes verified as per your advice. Evrything works fine. Ěs it possible to reboot the charger or something ??? Thks |
10-21-2014, 12:37 PM | #10 (permalink) |
Registered Users
|
You can perform a factory restore using the CCS. Save your presets first. The factory restore is on the firmware tab.
As I recall Revolectrix has a new office and warehouse in Batam. Though they may still be doing repairs in Singapore. Might be worth contacting them to see if you can swing by and drop off the charger for service. http://www.revolectrix.com/contact.htm
__________________
Revolectrix Ambassador - Charger Specialist Revolectrix.com 10% discount for Batteries GCAM16 |
Thread Tools | |